Products‎ > ‎

ECG Series

12 Channel ECG machine MVE1200G

posted Mar 25, 2019, 1:02 AM by MedsVise   [ updated Apr 23, 2019, 8:12 AM ]


https://sites.google.com/a/medsvise.com/main/products/ecg-series/mve1200g/mve1200g.jpg?attredirects=0
12 Channel ECG machine (MVE1200G)

https://wa.me/9613351640?text=I'm%20interested%20in%20MVC9200PLUS   https://docs.google.com/forms/d/e/1FAIpQLScxkf91Fzc1eD-nGoJeYnIFB3_uAb7GZfQf03qPIju_4P7z4Q/viewform?usp=pp_url
   Main Features
  • 8.3" Color TFT touch screen 
  • Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
  • Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
  • Multiply printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
  • Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.

6 Channel ECG machine MVE600G

posted Mar 25, 2019, 1:00 AM by MedsVise   [ updated Apr 23, 2019, 8:13 AM ]


6 Channel ECG machine (MVE600G)

https://wa.me/9613351640?text=I'm%20interested%20in%20MVC9200PLUS   https://docs.google.com/forms/d/e/1FAIpQLScxkf91Fzc1eD-nGoJeYnIFB3_uAb7GZfQf03qPIju_4P7z4Q/viewform?usp=pp_url
   Main Features
  • 8.3" Color TFT touch screen 
  • Adopt high-resolution thermal printing system (8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
  • Real-time and continuously record the clear and accurate ECG waveform and annotation character (including lead mark, sensitivity, paper speed and filter state, etc...).
  • Full-digital filter design, anti-baseline drift, AC and EMG interference.
  • Adjust the baseline automatically, optimize the print setting and optional rhythm leads.
  • In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
  • Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
  • With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency.
  • Sync collection for 12-lead ECG, multiply printing formats, including 2×6+1, 2×6, 3×4, 3×4+1, 4×3, 4×3+1, 6×2, 6×2+1, rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc.

3 Channel ECG machine MVE300G

posted Mar 25, 2019, 12:58 AM by MedsVise   [ updated Apr 23, 2019, 8:12 AM ]


3 Channel ECG Machine (MVE300G)

https://wa.me/9613351640?text=I'm%20interested%20in%20MVC9200PLUS   https://docs.google.com/forms/d/e/1FAIpQLScxkf91Fzc1eD-nGoJeYnIFB3_uAb7GZfQf03qPIju_4P7z4Q/viewform?usp=pp_url
  • Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
  • Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
  • Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
  • With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
  • Built-in memory stores up to 1000 cases, convenient for case review and statistic.
  • Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report. 
   Optional
  • PC sync Software with connection cable
REF352

3 Channel ECG Holter MVT9803

posted Mar 25, 2019, 12:55 AM by MedsVise   [ updated Apr 23, 2019, 8:14 AM ]


3 Channel ECG Holter Model: MVT9803

https://wa.me/9613351640?text=I'm%20interested%20in%20MVC9200PLUS    https://docs.google.com/forms/d/e/1FAIpQLScxkf91Fzc1eD-nGoJeYnIFB3_uAb7GZfQf03qPIju_4P7z4Q/viewform?usp=pp_url
   Main Features
  • The recorder can real-time store ECG data for 24-hour.
  • Arrhythmia analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
  • With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
  • Flexible analysis channel selection function, which ensures that any channels can be selected as the main analysis channel.
  • Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
  • All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.

PC Based ECG Workstation MVC8000

posted Mar 25, 2019, 12:53 AM by MedsVise   [ updated Apr 23, 2019, 8:16 AM ]


PC Based ECG Workstation (MVC8000)

https://wa.me/9613351640?text=I'm%20interested%20in%20MVC9200PLUS  https://docs.google.com/forms/d/e/1FAIpQLScxkf91Fzc1eD-nGoJeYnIFB3_uAb7GZfQf03qPIju_4P7z4Q/viewform?usp=pp_url
 The device acquires functions that including synchronous sampling of conventional 12-lead ECG data and 3-lead vector ECG data, various forms of analysis and diagnosis, report output and other functions. As an integrated ECG analysis system, the device can reflect user's heart movement timely and accurately. The device is applicable for ECG examination in medical and health institutions at all levels, providing accurate and reliable basis for diagnosis. The device is designed to transmit data by Bluetooth in real-time, which is very convenient for use.

   Main Features
  • Compact and portable design for Recorder, support both Wilson and Frank lead system. Indicator light can prompt device working status, such as charging, low battery and Bluetooth mode.
  • Adopt real-time sampling, display and storage mode, providing functions such as QRS wave analyzing in real-time, HR calculation and real-time printing, as well as multiple filter methods to avoid from baseline drift and interference.

Wireless Stress Test System MVC8000S

posted Mar 25, 2019, 12:49 AM by MedsVise   [ updated Apr 23, 2019, 8:17 AM ]


Wireless Stress Test ECG Analysis System (MVC8000S)

https://wa.me/9613351640?text=I'm%20interested%20in%20MVC9200PLUS    https://docs.google.com/forms/d/e/1FAIpQLScxkf91Fzc1eD-nGoJeYnIFB3_uAb7GZfQf03qPIju_4P7z4Q/viewform?usp=pp_url
The Stress ECG Analysis System consist of sampling hardware device, special software system and exercise equipment. Its functions include 12 leads ECG synchronously sampling, and data storage, ST segment analysis, ECG review in dynamic/static/superimposed during the whole exercise process, and trend chart analysis of multiple parameters, multiple printable report, etc. The patient's exercise state can be recorded timely and accurately, which reflects patient’s heart function, providing reliable data for doctors in diagnoses.

Main Features
  • Print ECG waveform in real-time during sampling process, record and save ECG data of whole process.
  • Observation of the changes of ST segment in real-time, enlargement display of user selected lead, automatic calculation of ST related data.
  • Adopt anti-interference technology to ensure the stabilization of baseline, reduce the effect on ECG waveform from EMG interference, baseline drift and AC interference.
  • Available for both standard and user-defined exercise scheme, automatic instantaneous notice of print and BP measure can be set according to exercise phrase.
  • Operator can mark events during exercise, the ECG waveform of marked event can be compared with current waveform. The event can be observed, edited and printed after excise.